ZX series of horizontal self-priming centrifugal pump operation

<

  ZX series pump is a horizontal self-priming centrifugal pump . Compared with other types of self-priming centrifugal pumps, this pump has the simplest structure, the most reliable structure, long working life, easy operation and maintenance, small volume, light weight and high efficiency because the pump itself has no check valve. ZX pump in industrial and agricultural production, emergency relief, such as drainage, fire fighting as an emergency pump to use more prominent performance.

    ZX pump widely used in petroleum, chemical, metallurgy, machinery, chemical fiber, food, energy, transportation and other industrial departments of urban water supply can also be used for agricultural irrigation and drainage. For the transport of water or viscosity less than 5 ° E, the temperature is below 80 ℃ Physical and chemical properties similar to other liquids.

    use

First, the preparation before the start of the inspection

1, the series ZX self-priming pump, according to the working conditions of the pump, respectively, using high-quality calcium-based butter and No. 10 oil for lubrication, if the pump with butter lubrication should be regularly filled with grease into the bearing housing, the use of oil-lubricated pump If the oil level is insufficient, add enough.

2, check the pump casing is higher than the upper edge of the impeller, if not enough, you can pump casing from the liquid directly into the pump body injection liquid storage should not start running under insufficient liquid storage , Otherwise it can not work, and easy to damage the mechanical seal.

3, check whether the rotating parts of the pump bump card phenomenon.

4, check the pump foot and the joints at the nut loose phenomenon.

5, check the pump shaft and motor spindle coaxiality and parallelism.

6, check whether the import pipeline leakage, if leaks, we must try to rule out.

7, open the suction pipe valve, slightly open (do not fully open) outlet control valve.

Second, start and operation

1, ZX self-priming pump, pay attention to the steering shaft is correct.

2, pay attention to whether there is no abnormal rotation and vibration.

3, pay attention to the pressure gauge and vacuum gauge reading, after the start when the pressure gauge and vacuum gauge readings after a period of fluctuation and indicate stability, indicating that the pump has been on the liquid, into the normal infusion operation.

4, the pump into the normal infusion operation before self-absorption process, special attention should be paid to increase the pump temperature, if this process is too long, the pump temperature is too high, then stop the pump to check the reason.

5, if the pump liquid temperature is too high and cause self-absorption difficulties, then you can temporarily shut down, the use of liquid back to the pump back to the pump or to the pump body plus reservoir directly to the pump to replenish the liquid, so that the pump The liquid cooling, and then start.

6, the pump in the course of work as a strong vibration and noise, there may be caused by pump cavitation, cavitation produced for two reasons: First, the import pipe flow rate is too large, and second, the suction stroke is too high. When the flow rate is too large, the outlet control valve can be adjusted to increase the pressure gauge readings, which should be promptly removed when there is a blockage in the inlet pipe. When the suction stroke is too high, the installation height of the pump may be properly reduced.

7, the pump in the course of work for some reason to stop the pump, need to start again, the outlet control valve should be slightly open (not fully closed), so that both self-priming gas discharge from the spit, but also to ensure that the sharp tip Under the responsibility of starting.

8, pay attention to check the pipeline system leakage phenomenon.

Third, stop the pump

1, must first close the discharge valve on the pipeline.

2, stop the pump rotation.

3, in the cold season, should be stored in the body of the pump body and bearing body cooling water in the room to vent to prevent cracking parts.

PET Bottle Recycling Machine

PET Bottle Recycling Machine is beglong to Plastic Recycling Machine , it is applied in PET waste bottle or sheet recycling field. Through crushing, washing and dry process, the waste bottle or sheet will become to be bottle flakes. The flakes are widely used in plastic industry, like sheet, and profile production. The clean flakes can be used to produce the polyester staple fiber, PET strap band, granules, PET transparent film and sheets, etc. The top class flakes can be used to blow bottles again.recycling machine can be designed on the basis of how dirty the flakes are, and make sure of the quality of the final products are very clean.recycling machine output we can supply is from 300kg/h to 2000kg/h.

Pet Bottle Recycling Machine,Plastic Bottle Recycling Machine,waste plastic recycling machine,plastic recycling plant

zhangjiagang sevenstars machinery co.,ltd , https://www.sevenstarmachienry.com