Structure and price of 100KV AC and DC high voltage test transformer

<

Structure of 100KV AC-DC High Voltage Test Transformer:

The iron core of this series is a single-phase core type, which is made of high-quality cold-rolled oriented silicon steel sheet. The fastening method adopts steel as a clamp. The high-voltage coil is a cylindrical multilayer tower, which is made of high-quality polyester enameled wire and high-voltage insulation material. The low voltage coil is outside and the instrument coil is a separate winding, which is generally 100V. The housing is octagonal and AC and DC high voltage test transformers above 10KVA are equipped with movable iron wheels. With light weight, small size, easy movement, superior performance and so on.

Technical indicators:

Rated capacity: 1~300KVA

Single rated output voltage:

(AC) 50, 100, 150, 200, 300KV

(DC) 70, 140, 210, 280KV

Rated input voltage: 200V, 400V

Ratios: 500/1, 1000/1, 1500/1, 2000/1, 3000/1

Ratio error: ≤±1.5%

Impedance voltage: <10%

After-sales service commitment, the host one year free maintenance, long-term service. Free software upgrades. Subject to conditions permitting, the company's technical staff will rush to the scene within 24 hours to provide quality services. Long-term cooperation units or bulk orderers can enjoy dealer surprise prices! !

Cross Flow Cooling Tower

Since the height of the filling is close to the tower top, the water eliminator does not occupy much space, and the overall height of the cross-flow tower is small, which makes it relatively compact compared with counter flow type, and therefore lower air inlet speed and power consumption as well.


The cross-flow tower adopts a water distribution system that will let the water drop fall naturally by gravity. Thereby, water distribution holes are not easy to be blocked, as water distribution is even and maximizes the performance of the tower fillings. The inspection manhole also enables routinely maintenance without machine shutdown.


A lower part of the cross-flow tower filling is submerged in the water, so that the water flows through the surface of the filling and directly falls into the below tank, making low noise.


The cross-flow tower fan is located in the middle of the Cooling Tower, while the filling, on both sides of the tower. So the amount of splashing water is very small.

Cross Flow Cooling Tower,Cooling Tower Cools Water,Induced Draught Cooling Tower,Induced Draft Cross Flow Cooling Tower

Guangdong Jiema Energy Saving Technology Co.,Ltd , https://www.heatexchangerjm.com