Refrigerated and Heating Circulator Air Cooled Chiller Hrt-25n

<

Model NO.: Hrt-25n
Certification: ISO, CE
Condition: New
Temperature Range: -50~200 Degree
Circulation Pump: Max75L/Min 2bar
Tank Volume: 8L
Compressor: Tecumseh
Refrigerant: R404A
Connection Size: Dn15
Evaporator: Plate Heat Exchanger
Weight: 320kg
Power: AC 220V 50Hz 4.5kw(Max)
Case Material: Cold Rolled Steel
Trademark: LNEYA
Transport Package: Standard Wooden Case
Specification: 400*600*1150 mm
Origin: Wu Xi
HS Code: 8418692090

Description:
The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the  tank temperature is limited to 60ºC.
The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature; Wide working temperature range of heat transfer oil; The entire circulation system without use of mechanical and electric valve.


Features:

1.Wide working temperature range with cooling and heating function, temperature range: -20~200ºC.
2.With 2pcs of LED display controller, can show the setting temperature & actual value, and alarm value for overtemperature. 3.Efficient fast, simple topping up liquid.
4.Ensure fast cooling at high temperature and can acheive 200ºC ~ -20ºC temperature control continuously.
5.The cycle system is closed, there is no oil mist and water vapor happend, so as to assure the lab safety and heat transfer fluid lifetime.
6.Use copeland brand compressor,circulation pump,stable performance and reliable quality.
7.Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
8.Use the same kind of heat conducting in the whole heating-cooling cycle when control heat conducting medium temperature.
9.High-lift design and meet the long-distance transportation of heat conducting medium.

Model HRT-25N
Temperature range ºC -50ºC~250ºC
Controller PID adaptive controller
Temp. control Heat-conducting medium outlet temp. control
Communication protocol MODBUS RTU Protocol, RS 485 Interface
Temperature feedback Heat-conducting medium temperature feedback PT100
Temp. accuracy ±0.5ºC
Heating power 2500W
Cooling capacity 250ºC 2000W
100ºC 2000W
20ºC 2000W
0ºC 1800W
-20ºC 850W
-40ºC 250W
Circulation pump Max25L/min
1BAR
Tank volume 8L
Be equipped with extra connection of expansion tank(DN15)
Compressor Tecumseh
Evaporator Plate heat exchanger
Operation panel Display setting temperature, medium outlet and return temperature; 7-inch 
Touch screen display
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, 
overload relay, thermal protection device,liquid low level protection, high 
temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high 
temperature and no water vapor at low temperature,pressure do not rise 
up when system is running. The system will supplement oil automatically at 
low temperature.
Refrigerant R-404A
Connection size DN-15
Dimension(mm)   (air-cooled) 400*600*1150
Weight  (air-cooled) 160kg
Power AC 220V 50HZ
4.5kW (max)
Case material Cold rolled steel
Optional MODBUS RTU Protocol, RS 232 Interface
Optional power 220V 60HZ three-phase source, 440V~460V 60HZ three-phaseÂ