China-Electrical-Riveting-Stamping-Contact-Components

<

About our products
Through the improvement of mold design during stamping, add welding or tapping process in mold and fiber sensor to detect missing welding, thus achieved the integration of stamping, welding/tapping and inspection. The lifetime of each tooling is 5,000,000 times, and speed could be more than 70 times/min. It greatly increased capacity, reduced labor and process cost, and miantain more stable quality to compare with traditional manual welding.

Type : Forming in mold through feeding silver wire, contacts or profile tape, double side welding in one step also be available.

Material : Terminal/Spring: Copper, Brass, Phosphor copper, copper nickel, beryllium copper, white copper, Nickel, Aluminium, Iron, stainless steel, Monel,Clad metal ect.
Contacts: Ag, AgNi, AgCu, AgCuNi, AgCdO, AgSnO2, AgSnO2In2O3

Application Scope : Mainly used in Thermostat, Protector, Switch socket,  Controller, and other middle or low voltage applances, and so on.

Capacity : 25,000,000pcs/month with more than 20 sets of equipments.





Why Choose Us?

1. Our team




2.Our customers

3.Quality



More informations about us, pls visit our website: www.hkbestech.com







 

Features of the Water Cooling Tower,

1,Cooling tower is mainly used for cooling in air conditioning system, frozen series, injection molding, leather, foam, power generation, steam turbine, aluminum processing, air compressors, industrial cooling water and other fields,

2, Cooling tower is most used for air conditioning cooling, freezing, plastic chemical industry.


Advantages of the Water Cooling Tower,

1, Light structure compact
2, Convenient assembly, durable, good cooling effect.
3, Resistance to irradiation of ultraviolet


Specification  of the Water Cooling Tower,

Model

RS-ST

8

10

15

20

25

30

Flow

cbm/h

6.23

7.81

11.7

15.62

19.51

23.4

Air volume

cmm

70

85

140

160

200

230

Motor

KW

0.18

0.18

0.37

0.56

0.75

0.75

Sound volume(16M)

KBA

45.5

47

48

50

52

54

Approx.N.W.

KG

42

46

54

67

98

116

Operating weight

kg

180

190

290

300

500

530

Basin diameter

mm

945

945

1195

1195

1400

1650

Tower hight

mm

1385

1535

1420

1595

1825

1710

 

Model

RS-ST

150

175

200

225

250

300

Flow

cbm/h

117

136.8

156.24

175.5

195.12

234

Air volume

cmm

950

1150

1250

1500

1750

2000

Motor

KW

2.25

3.75

3.75

5.5

5.5

7.5

Sound volume(16M)

KBA

60

60

60

54

55

56

Approx.N.W.

KG

580

810

830

1050

1080

1760

Operating weight

kg

1680

1910

1930

2770

2800

3930

Basin diameter

mm

2900

3310

3310

4120

4120

4730

Tower hight

mm

2555

3165

3165

3580

3580

3680

 

Model

RS-ST

400

500

600

700

800

1000

Flow

cbm/h

312.1

372.4

468

547.2

626.4

781.2

Air volume

cmm

2400

2600

3750

4000

5000

5500

Motor

KW

7.5

7.5

11

11

15

15

Sound volume(16M)

KBA

59

60

60

60.5

61

61.5

Approx.N.W.

KG

2920

3010

4050

4200

4900

5100

Operating weight

kg

5900

6000

9450

9650

12100

12400

Basin diameter

mm

5600

5600

6600

6600

7600

7600

Tower hight

mm

3870

3870

4900

4900

4950

4950

 

Water Cooling Tower Project K 

Water Cooling Towers Structure Diagram 

Cooling Towers

Cooling Towers,Industry Cooling Tower,Water Cooling Tower,Round Cooling Tower