Reading Braille: Braille Instructions,Braille Alphabet,Braille Printing,Braille Packaging Box Shanghai Caide Printing Co.,Ltd. , https://www.caidelabels.com
             Â
Â
ABOUTÂ THEÂ MACHINE
This fully Automatic Capsule Filling adopts multibore dosing, intermittent motion & frequency control.Â
High speed, high performance machine that incorporates latest international design and is built with precision using most appropriate material and up to date manufacturing systems.
It is suitable for automatic completion of Capsule feeding, separating, filling waste capsule rejection,Â
closing, finished capsule ejection.
 Functional Sequence
1. Empty capsule loading and separation
2. Lower Module segment move down and outward
3. Powder or pellet filling
4. Reserve station
5. Removal of separated capsule
6. Lower module segment move backÂ
7. Capsule locking
8. Discharge of filled capsuleÂ
9. Module segment cleaning
Â
NJP-2-200C Capsule filling machine is suitable for hospitals, labs, medical research institutions,small pharmaceutical and health factories with the characteristics of the following:
1. small,low power consumption, esay to operate and clean.
2.Auto loading of powder into hopper of machine in dust free manner to reduce crossÂ
contamination & better adherence to GMP.
2.closed system protect your product from contaminants, and allow a dust-free
production environment for better health and easier cleaning
3.Pellet filling device to fill granules & pellets
4. All electrical & Pneumatic can be international make
5.The movable parts are in full enclosure, having excellent lubricating conditions.
6. Dust collectors are provided for rejected capsule suction & powder suction.
7. man-machine interface,  Timing frequency-conversion, programmable controlled.
8. quick changeover. machine parts are made by CNC computer machine
9.Can be Designed to meet customer's technical requirements.Â
 Powder filling device
 Powder in hopper is fed and its level is maintained into the tub of tamping assembly by an automated auger.Fully enclosed construction ensures minimum wastage.
Pellet filling device
Able to adjust the thickness of pellet blocks so that it allows accurate measuring of drug weight that is inserted into the capsule.Also, as it is designed in a simple structure for easy disassembly and assembly of the pellet blocks, it will significantly reduce the setting time.
Fully enclosed Rotary table
The turret has a rotating indexing motion.Â
Function of the turret is to transport capsules from one station to another. FullyÂ
enclosed structure protects moving components from dust contamination.
Technical Parameter
Model
NJP-200
NJP-400
NJP-800
NJP-1200
NJP-2000
NJP-3500
Capacity (capsule/minute)
200
400
800
1200
2000
3500
Bores
2
3
6
9
18
26
Capsule size
00#-5#
00#-5#
00#-5#
00#-5#
00#-5#
00#-5#
Power Supply
It can be change by different country different power supply
Vacuum Pump
0.02-0.06MPa
Noise
Less than 80dB(A)
Dust Suction
700cubicmeter/HÂ Â Â Â Â Â Â 2*105MPa
Overall Dimension
700×800×1700mm
960×1000×1900mm
 1300×1450×2300mm
Â
1. Familiarize yourself with the Braille alphabet, which consists of six dots arranged in two columns of three dots each. Each dot or combination of dots represents a different letter, number, punctuation mark, or special symbol.
2. Place your fingertips lightly on the Braille text, typically on a page or surface made specifically for Braille.
3. Feel the dots with your fingertips and identify the patterns to determine the corresponding letters, numbers, or symbols.
4. Move your fingertips systematically across the Braille text, reading from left to right and top to bottom, just like reading regular text.
Writing Braille:
1. Learn the Braille alphabet and practice writing each letter, number, punctuation mark, and special symbol.
2. Use a Braille slate and stylus, which is a tool specifically designed for writing Braille. The slate has rectangular openings to hold the paper, and the stylus is used to press the dots onto the paper through the openings.
3. Place a piece of Braille paper or cardstock into the slate, ensuring it is aligned properly.
4. Hold the stylus like a pen or pencil and press the appropriate dots onto the paper, one at a time, following the Braille alphabet.
5. Lift the stylus after each dot is pressed to avoid smudging or blending the dots together.
6. Continue writing the desired text, moving from left to right and top to bottom on the paper.
7. Review your writing by feeling the dots with your fingertips to ensure accuracy.
It is important to note that learning Braille may require time and practice, as it is a tactile skill that requires the ability to distinguish between the different dot patterns. However, with dedication and persistence, individuals can become proficient in reading and writing Braille.
Capsule Mold
Model NO.: mold
Customized: Customized
Condition: New
Warranty: 1 Year
Function: Automatic
Material: Stainless Steel
Operation: Stable
Trademark: GLOBAL
Transport Package: Wooden Box
Specification: 10000-492000
Origin: Wenzhou
HS Code: 8422303090