8tons 10tr Residential Water-Cooled Type Chiller

<

  • Model NO.: hwwc
  • Cooling Method: Water-cooled
  • Selected Voltage: 220V, 380V, 160V, 440V etc.
  • Noise Level: Ultra Low
  • Application Machine: Combination machine
  • Name: R407c Water-Cooled Industrial Water Chiller
  • Norminal Input Power: 2.7-31.5kw
  • Chilled Water Fresistance: 28-43kpa
  • Refrigerant: R22/R407cr410A etc
  • Cooling Water Resistance: 28-45 Kpa
  • Trademark: Headpower
  • Specification: 1unit/case
  • HS Code: 8418692090
  • Type: Water-Cooled
  • Unit Structure: Integral
  • Compressor Number: It Depend on The Cooling Capacity
  • Application Fields: Air Conditioning
  • Certification: ISO, CE
  • Cooling Capacity: 15-150kw
  • Chilled Water Flow: 3-27.5CMH
  • Compressor Type: Hermetic Scroll
  • Cooling Water Flow: 3.3-34.5CMH
  • Weight: 160-560kgs
  • Transport Package: Plastc+Foam+Woden Case
  • Origin: Guangdong Foshan
1)The Feature of  8tons 10tr residential water-cooled type chiller 
a.High Pferformance
High-performance hermetic scroll compressor and multi-system optimized design ensures the unit'scoefficent of performance (COP value) is up to 5.4 during refrigeration or upt to 4.5 during heat supply
b.Excellent partial load characteristics
The unit can run normally even in lower refrigerantion output, and the microcomputer control system is able to rationally control the modulus running,meanwhile the refrigeration output of the modulus can be regulated by starting a number of compressors, therefore high-efficient running can be achieved even in the scope of low loads,ensuring the otimal matching of the outut and needed refrigeration and minimizing energy consumption.
In addition,for the business plazasor office bulidings which are leased,sold or used in separate floors,when smaller cold or heat loads are required for individual rooms, using traditional central air conditioneris not only a great waste of energy,but impairs the unit. 
In these cases, modular units are the best choice.
c.Small size and compact structure
Modular design idea is incorporated into all parts of the unit;pipes and core parts of the unit enjoy rational arrangement;the unit is of smaller sizes, light weight(a single module weight280-560kg only),covers smaller area;meanwhile it can be moved frelly without being affected by external construction conditions,especially suitaable for restructuring works.
d.Modular unit design and picked parts
The shell-and-bube heat exchanger is used,enjoys smaller sizes, safety,no leakage,high heat exchange efficiency,smaller heat loss and resistance,and easy maintenance.
e.One unit having three purposes
Such three functions as refrigeration,heating and provisionof living water can be performed.
f .The unit enjoys lower overall running noise(56-60dB)
High quality compressor and powerful external sound absorption housing are used and achieve super-low noise running
g.The unit is easy for assembly and maintenance,covers smaller space
The unit is delivered after refrigerant and compressor lubricating oil are filled and meters are calibrated,and it can be put into use after onsite assembly,pipe erection and electric wire conection.
h.Exclusive high-temperature water source unit
High outlet water temperature with maximum 65ºC is sufficient to provide living hot water,superior to traditional heat supplysystems.
The heating efficiency is over 4 and is safe anf reliable

2)Product model:
Performance                                                                    Model NO. HWWC15 HWWC18 HWWC28 HWWC38 HWWC56 HWWC75 HWWC110 HWWC150
Cooling Conditions Norminal Cooling Capacity KW 15 18 28 38 56 75 110 150
Norminal Input Power KW 2.7 3.9 5.3 7.9 10.5 15.8 23.5 31.5
Evaporator Inlet/ Outlet Chilled Water Temperature ºC 7~12
Chilled Water Flow m³/h 3 3.5 6 6.9 12 13.8 20.8 27.5
Chilled Water Resistance Kpa 28 30 32 32 35 38 42 43
Condenser Inlet/ Outlet Cooled Water Temperature ºC 30/35
Cooled Water Flow m³/h 3.3 4.5 6.5 8.6 13 17.2 25.8 34.5
Cooled Water Resistance Kpa 28 30 32 35 38 40 44 45
Refrigerant Medium R22
Compressor Type Hermetic Scroll
QTY 1 1 2 2 3 2 3 4
Electric Performance Voltage 380V/3PH/50HZ
Security Prection High and Low Pressure Protection, Anti Frozen Protection, Compressor Overheat Protection, Water Short Protection
Inlet/ Outlet Chilled Water Pipe DN 25 25 32 40 50 50 65 50*2
Inlet/ Outlet Cooled Water Pipe DN 25 25 32 40 50 50 65 50*2
Unit Dimension L mm 1200 1400 1600 1800 2200 2500 2800 2500
W mm 650 650 650 650 800 800 1000 1500
H mm 800 800 1000 1200 1200 1500 1500 1500
Noise Level dB(A) 48 48 50 53 55 56 58 60
Weight kg 160 170 180 190 250 280 400 560
                       
Note: 1. Norminal cooling conditions: condenser inlet water temperature 30ºC, outlet water temperature 35ºC; evaporator inlet water temperature 12ºC, outlet water temperature7ºC.
         2. The company reserves the right to improve prodct designs without prior notice.
3) Dispaly:
 
4)Packing and shipping


5)Our company file


5)Project and client:

No

Project Name ( China)

Industry

Area

1

Zhongshan people hospital

Hospital

Zhongshan

2

Hankou Railway Station, Union Hospital, Wuhan Branch

Hospital

Wuhan

3

Wuhan City, Wuchang Railway Hospital

Hospital

Wuhan

4

Three townships Zhongshan People's Hospital

Hospital

Zhongshan

5

Zhujiang hospital of Guangzhou

Hospital

Guangzhou

6

Zhongshan Garden Hotel

Hotel   industry

Zhongshan

7

Western Sunshine Hotel, Zhongshan

Hotel   industry

Zhongshan

8

Shunde Golden Hotel

Hotel   industry

Foshan

9

East China Hotel in Guangzhou

Hotel   industry

Guangzhou

10

Nanyou Zhuhai hotel

Hotel   industry

Zhuhai

No

Company Name ( Overseas)

Product

Country

1

SB Global Energy

Air cooled ducted split

Holland

2

Bentos pharmaceutical products Ltd.

Clean air conditioners

Nigeria

3

SOGAMEF

Air cooled chiller

Gabon

4

SeaService shipping

Marine air conditioner

Russia

5

EURO STANDARD LIMITED

Fresh Air Handling Unit

New Zealand

6

Henrich trading center

Air cooled/water cooled air conditioner

Philippines

7

Marine Engineering Systems Pte.Ltd

AHU, chiller,etc

Singapore

8

Elektro Werner Heitzinger

Heat recovery air handling unit

Austria

9

Nyborg Marine Equipments AS

Marine Air Handling Units

Norway

10

Wilfred Limited

Heat recovery air handling unit

UK
 
 

Carrie Mak
GuangDong Head-Power Air Conditioning Co.,Ltd.
Add: Shiling Chenbian Section, 321 National Highway, Shishan Town,
Nanhai District, Foshan,Guangdong,China.
Mobile :86-15024293999
 Fax:86-757-86688063
 
http://www.china-headpower.com

AC Hydraulic Power Unit

Ac Hydraulic Power Unit,Double Acting Cylinders Stainless Ac,Dump Truck Hydraulic Ac Power Unit,Melt Welder Hydraulic Power Unit

Huaian Haotian Hydraulic Co.,Ltd , https://www.hahtyy.com