Model NO.: hwwc
-
Cooling Method: Water-cooled
-
Selected Voltage: 220V, 380V, 160V, 440V etc.
-
Noise Level: Ultra Low
-
Application Machine: Combination machine
-
Name: R407c Water-Cooled Industrial Water Chiller
-
Norminal Input Power: 2.7-31.5kw
-
Chilled Water Fresistance: 28-43kpa
-
Refrigerant: R22/R407cr410A etc
-
Cooling Water Resistance: 28-45 Kpa
-
Trademark: Headpower
-
Specification: 1unit/case
-
HS Code: 8418692090
-
Type: Water-Cooled
-
Unit Structure: Integral
-
Compressor Number: It Depend on The Cooling Capacity
-
Application Fields: Air Conditioning
-
Certification: ISO, CE
-
Cooling Capacity: 15-150kw
-
Chilled Water Flow: 3-27.5CMH
-
Compressor Type: Hermetic Scroll
-
Cooling Water Flow: 3.3-34.5CMH
-
Weight: 160-560kgs
-
Transport Package: Plastc+Foam+Woden Case
-
Origin: Guangdong Foshan
1)The Feature of  8tons 10tr residential water-cooled type chillerÂ
a.High Pferformance
High-performance hermetic scroll compressor and multi-system optimized design ensures the unit'scoefficent of performance (COP value) is up to 5.4 during refrigeration or upt to 4.5 during heat supply
b.Excellent partial load characteristics
The unit can run normally even in lower refrigerantion output, and the microcomputer control system is able to rationally control the modulus running,meanwhile the refrigeration output of the modulus can be regulated by starting a number of compressors, therefore high-efficient running can be achieved even in the scope of low loads,ensuring the otimal matching of the outut and needed refrigeration and minimizing energy consumption.
In addition,for the business plazasor office bulidings which are leased,sold or used in separate floors,when smaller cold or heat loads are required for individual rooms, using traditional central air conditioneris not only a great waste of energy,but impairs the unit.Â
In these cases, modular units are the best choice.
c.Small size and compact structure
Modular design idea is incorporated into all parts of the unit;pipes and core parts of the unit enjoy rational arrangement;the unit is of smaller sizes, light weight(a single module weight280-560kg only),covers smaller area;meanwhile it can be moved frelly without being affected by external construction conditions,especially suitaable for restructuring works.
d.Modular unit design and picked parts
The shell-and-bube heat exchanger is used,enjoys smaller sizes, safety,no leakage,high heat exchange efficiency,smaller heat loss and resistance,and easy maintenance.
e.One unit having three purposes
Such three functions as refrigeration,heating and provisionof living water can be performed.
f .The unit enjoys lower overall running noise(56-60dB)
High quality compressor and powerful external sound absorption housing are used and achieve super-low noise running
g.The unit is easy for assembly and maintenance,covers smaller space
The unit is delivered after refrigerant and compressor lubricating oil are filled and meters are calibrated,and it can be put into use after onsite assembly,pipe erection and electric wire conection.
h.Exclusive high-temperature water source unit
High outlet water temperature with maximum 65ºC is sufficient to provide living hot water,superior to traditional heat supplysystems.
The heating efficiency is over 4 and is safe anf reliable
2)Product model:
Performance                                                                    Model NO. |
HWWC15 |
HWWC18 |
HWWC28 |
HWWC38 |
HWWC56 |
HWWC75 |
HWWC110 |
HWWC150 |
Cooling Conditions |
Norminal Cooling Capacity |
KW |
15 |
18 |
28 |
38 |
56 |
75 |
110 |
150 |
Norminal Input Power |
KW |
2.7 |
3.9 |
5.3 |
7.9 |
10.5 |
15.8 |
23.5 |
31.5 |
Evaporator |
Inlet/ Outlet Chilled Water Temperature |
ºC |
7~12 |
Chilled Water Flow |
m³/h |
3 |
3.5 |
6 |
6.9 |
12 |
13.8 |
20.8 |
27.5 |
Chilled Water Resistance |
Kpa |
28 |
30 |
32 |
32 |
35 |
38 |
42 |
43 |
Condenser |
Inlet/ Outlet Cooled Water Temperature |
ºC |
30/35 |
Cooled Water Flow |
m³/h |
3.3 |
4.5 |
6.5 |
8.6 |
13 |
17.2 |
25.8 |
34.5 |
Cooled Water Resistance |
Kpa |
28 |
30 |
32 |
35 |
38 |
40 |
44 |
45 |
Refrigerant |
Medium |
R22 |
Compressor |
Type |
Hermetic Scroll |
QTY |
1 |
1 |
2 |
2 |
3 |
2 |
3 |
4 |
Electric Performance |
Voltage |
380V/3PH/50HZ |
Security Prection |
High and Low Pressure Protection, Anti Frozen Protection, Compressor Overheat Protection, Water Short Protection |
Inlet/ Outlet Chilled Water Pipe |
DN |
25 |
25 |
32 |
40 |
50 |
50 |
65 |
50*2 |
Inlet/ Outlet Cooled Water Pipe |
DN |
25 |
25 |
32 |
40 |
50 |
50 |
65 |
50*2 |
Unit Dimension |
L |
mm |
1200 |
1400 |
1600 |
1800 |
2200 |
2500 |
2800 |
2500 |
W |
mm |
650 |
650 |
650 |
650 |
800 |
800 |
1000 |
1500 |
H |
mm |
800 |
800 |
1000 |
1200 |
1200 |
1500 |
1500 |
1500 |
Noise Level |
dB(A) |
48 |
48 |
50 |
53 |
55 |
56 |
58 |
60 |
Weight |
kg |
160 |
170 |
180 |
190 |
250 |
280 |
400 |
560 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Note: 1. Norminal cooling conditions: condenser inlet water temperature 30ºC, outlet water temperature 35ºC; evaporator inlet water temperature 12ºC, outlet water temperature7ºC. |
         2. The company reserves the right to improve prodct designs without prior notice. |
3)Â Dispaly:
Â
4)Packing and shipping
5)Our company file
5)Project and client:
No |
Project Name (Â China) |
Industry |
Area |
1 |
Zhongshan people hospital |
Hospital |
Zhongshan |
2 |
Hankou Railway Station, Union Hospital, Wuhan Branch |
Hospital |
Wuhan |
3 |
Wuhan City, Wuchang Railway Hospital |
Hospital |
Wuhan |
4 |
Three townships Zhongshan People's Hospital |
Hospital |
Zhongshan |
5 |
Zhujiang hospital of Guangzhou |
Hospital |
Guangzhou |
6 |
Zhongshan Garden Hotel |
Hotel   industry |
Zhongshan |
7 |
Western Sunshine Hotel, Zhongshan |
Hotel   industry |
Zhongshan |
8 |
Shunde Golden Hotel |
Hotel   industry |
Foshan |
9 |
East China Hotel in Guangzhou |
Hotel   industry |
Guangzhou |
10 |
Nanyou Zhuhai hotel |
Hotel   industry |
Zhuhai |
No |
Company Name (Â Overseas) |
Product |
Country |
1 |
SB Global Energy |
Air cooled ducted split |
Holland |
2 |
Bentos pharmaceutical products Ltd. |
Clean air conditioners |
Nigeria |
3 |
SOGAMEF |
Air cooled chiller |
Gabon |
4 |
SeaService shipping |
Marine air conditioner |
Russia |
5 |
EURO STANDARD LIMITED |
Fresh Air Handling Unit |
New Zealand |
6 |
Henrich trading center |
Air cooled/water cooled air conditioner |
Philippines |
7 |
Marine Engineering Systems Pte.Ltd |
AHU, chiller,etc |
Singapore |
8 |
Elektro Werner Heitzinger |
Heat recovery air handling unit |
Austria |
9 |
Nyborg Marine Equipments AS |
Marine Air Handling Units |
Norway |
10 |
Wilfred Limited |
Heat recovery air handling unit |
UK Â Â |
Carrie Mak
GuangDong Head-Power Air Conditioning Co.,Ltd.
Add: Shiling Chenbian Section, 321 National Highway, Shishan Town,
Nanhai District, Foshan,Guangdong,China.
Mobile :86-15024293999
 Fax:86-757-86688063
Â
http://www.china-headpower.com
AC Hydraulic Power Unit
Ac Hydraulic Power Unit,Double Acting Cylinders Stainless Ac,Dump Truck Hydraulic Ac Power Unit,Melt Welder Hydraulic Power Unit
Huaian Haotian Hydraulic Co.,Ltd , https://www.hahtyy.com